116. A wet scrubber connected to an incinerator must have a system that continuously measures and records the gas pressure loss through the scrubber and a differential pressure gauge accurate to within 0.5 kPa.
In addition, it must have a system that continuously measures and records the scrubbing liquid pressure at the delivery pipe inlet and have a pressure gauge accurate to within 10% of the rated pressure in that pipe.
O.C. 501-2011, s. 116; O.C. 1228-2013, s. 18.
116. A wet scrubber connected to an incinerator must have a system that continuously measures and records the gas pressure loss through the scrubber and a differential pressure gauge accurate to within 0.5 kPa.
In addition, the incinerator must have a system that continuously measures and records the scrubbing liquid pressure at the delivery pipe inlet and have a pressure gauge accurate to within 10% of the rated pressure in that pipe.